I calculated minimum length of conduit (added some overage). | I calculated minimum length of conduit (added some overage). | ||
2" @ | 2" @ 142' | ||
3/4" @ | 3/4" @ 122' | ||
Carlon Resi-Gard Flexible Raceway | Carlon Resi-Gard Flexible Raceway | ||
Need | Need three standard length coils of 2" P/N SCJ4X1C-100 50' | ||
Need | Need two standard length coil of 3/4" P/N SCE4X1-100 100' length | ||
Conduit Clamps (don't forget to account for 2 screws, 2 nuts, or 2 bolts per clamp) | Conduit Clamps (don't forget to account for 2 screws, 2 nuts, or 2 bolts per clamp) |
Revision as of 03:19, 13 September 2009
Home Structured Cable System
Distribution Center
Since this is retrofit on existing 20+ year old house I decided to securely bolt 3/4" plywood to wall and build a distribution center. The metal panels from various vendors would have been nice but the costs did not outweigh the benefits. When we build a new house some day I'll get the fancy distribution panels.
I'll post details once I'm done.
Distribution Modules
LANshack products:
Universal Patch Panel Mounting for patch panel mounting
Cables & Wires
Cat5e cables (data & voice) RG6 coaxial
Conduit
Carlon for cable conduit
I calculated minimum length of conduit (added some overage).
2" @ 142'
3/4" @ 122'
Carlon Resi-Gard Flexible Raceway
Need three standard length coils of 2" P/N SCJ4X1C-100 50'
Need two standard length coil of 3/4" P/N SCE4X1-100 100' length
Conduit Clamps (don't forget to account for 2 screws, 2 nuts, or 2 bolts per clamp)
3/4" P/N SCE977EC
2" P/N SCE977JC
ABA Cable for bulk cable
LANshack products:
Rip Tie cable ties
Multimedia Outlets
Need 10 Carlon Old Work Brackets P/N SC100RR 1-Gang